ES 95 AZ
Features/Options
- Thermoplastic enclosure
- Double insulated

- Slow action
, change-over contact with double break - Wiring compartment
- Mounting details to EN 50 047
- Transversely slotted mounting holes
- Actuator heads can be repositioned in factory in 4 x 90° steps
- With connector M12 x 1.5, 4-pole available
- Gold-plated contact possible on request
- Ex-version available
Product image

Technical data
| Standards | EN ISO 13849-1; IEC/EN 60947-5-1; EN 1088 |
|---|---|
| Enclosure | glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0 |
| Actuator | stainless steel 1. 4301 |
| Degree of protection | IP 67 to IEC/EN 60529 |
| Contact material | silver |
| Switching system | slow action, positive break NC contact ![]() |
| Switching elements | change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges |
| Connection | M3 screw terminals |
| Cable section | max. 1.5 mm 2 (incl. conductor ferrules) |
| Cable entry | 1 x M20 x 1.5 |
| B10d (10% Load) | 2 millionen |
| TM | max. 20 years |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | 6 A |
| Ie/Ue | 6 A/400 VAC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 6 A gL/gG D-fuse |
| Positive break travel | 9 mm |
| Ambient temperature | –20 °C … +80 ºC |
| Mechanical life | > 1 million operations |
| Approvals | ![]() |