Ex 14 AZ

Features/Options

  • Thermoplastic enclosure
  • Double insulation Schutzisoliert
  • Slow action Zwangsöffnung, 1 NC contact
  • Version with pre-wired cable output on side available
  • Pre-wired cable
  • Special version only for dust Ex zone 22 available
  • N.B.: Please state required approvals for Russia, China, Brazil and North America with your order!

Product image

 

Technical data

Standards IEC/EN 60947-5-1; 95/16/EG,
EN 81-1; EN 81-2; EN 1088;
EN 60079-0; EN 60079-1;
EN 60079-31
Enclosure glass-fibre reinforced, shock-resistant thermoplastic, auto-extinguishing UL 94-V0
Actuator stainless steel 1.4301
Degree of protection IP 65 to IEC/EN 60529
Contact material silver
Switching system slow action, NC contact with positive break Zwangsöffnung
Switching system 1 NC contact
Connection pre-wired cable H05VV-F
Cable section 2 x 0.75 mm2
Cable length 1.5; 3; 5; 6 or 10 m
B10d (10%load) 2 million
TM max. 20 years
Uimp 4 kV
Ui 250 V
Ithe 3 A
Ie/Ue 3 A/250 VAC; 0,2 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 3 A gL/gG D-fuse
Positive break travel 3,5 mm
Ambient temperature –20 °C … +65 °C
Mechanical life > 1 million operations
Ex-marking EEx geprüft II 2G Ex d IIC T6/T5 Gb
EEx geprüft II 2D Ex tb IIIC
T80°C/T95°C Db IP65
IECEx Ex d IIC T5/T6 Gb
Ex tb IIIC T80°C/T95°C Db IP65
Approvals PTB 03 ATEX 1070 X
IECEx PTB 06.0098X