Ex 355

Features/Options

  • Ex zone 1 and 21
  • Metal enclosure
  • Mounting and switching details to EN 50 041
  • Wiring compartment
  • 3 cable entries
  • Actuating elements can be repositioned by 4 x 90°
  • Rocking lever can be repositioned by 10° steps
  • Special version only for dust Ex zone 22 available
  • With gold-plated contacts available on request
  • N.B.: Please state required approvals for Russia and Brazil with your order!

Product image

 

Technical data

Standards EN 60947-5-1; EN 1088;
EN 60079-0, EN 60079-1,
EN 60079-7, EN 60079-31
Design mounting dimensions and switching points to DIN EN 50 041
Enclosure zinc die casting, enamelled
Switch insert Ex 95
Degree of protection IP 67 to IEC/EN 60529
Contact material silver
Switching system slow action, positive break
NC contact Zwangsöffnung
Switching elements change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges
Connection M3 screw clamps
Cable section max. 1.5 mm²
(incl. conductor ferrules)
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0.25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –20 °C … +60 ºC
Mechanical life > 1 million operations
Switching frequency 1800/h
Repeat accuracy ±0.1 mm
Contact gap max. 2 x 3.5 mm
Ex marking EEx geprüft II 2G Ex de IIC T6/T5 Gb,
EEx geprüft II 2D Ex tb IIIC
T80°C/T95°C Db IP65
IECEx Ex de IIC T6/T5 Gb,
Ex tb IIIC T80°C/T95°C Db IP65
Approvals BVS 04 ATEX E 126,
IECEx BVS 07.0013